<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-03 12-56-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.90 MHz 5/5, 76 dBuV SRF2
Pilot RDS Phase Difference
6.9 kHz 2.3 kHz 56 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
0 kHz 2 kHz 17962 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-18,0 dBr -13,11 dBr -2,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SRF2 " 43B2 7 (Culture) 0 1 1 1 11:55, 3.08.2025
RT
"Ludwig van Beethoven - Klavierkonzert Nr. 3 c-Moll op. 37 "
AF EON
88.5, 91.7, 93.0, 93.2, 93.7, 94.0, 94.9, 95.4, 96.6, 97.3, 97.7, 99.0, 99.1, 99.4, 99.5, 99.6, 100.7, 102.5, 103.2, 104.1, 104.9 MHz 43B3, 43B1
FM Scope Max at: 2 kHz MIN: 0 kHz % above 76 kHz: 0,0000 Acquired: 2025/08/03 12.55.07 Total samples: 17962 Equivalent time: 0:14:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: -2,9 dBr MIN: -18,0 dBr AVE: -13,11 dBr % above 12,2 dBr: 0,0 Last value: -4,3 dBr (2025/08/03 12.55.06) 12.42 12.44 12.46 12.48 12.50 12.52 12.54 -15 -10 -5 0 Pm [dBr]